Skip to content
Biogenica

Certificates of analysis for peptide products.

11X testing including purity, identity and content testing with a certificate your customers can verify themselves.

10% off your first order with code WELCOME10 Contact the laboratory for volume discounts

Example Biogenica certificate of analysis: purity, net peptide content, identity and pH results for a 10mg lyophilized peptide, with a QR code for verification
Example certificate. Click to view full report
Standard turnaround
7 to 10 business days from receipt
Rush
Three business days, guaranteed or the fee is credited back
Next day
Next business day

The tests

What each one answers, and what it costs on its own.

Purity, Net Content, Identity, pH & Fentanyl

One LC-MS/MS analysis answers all five questions, so they are ordered and priced as a single test.

$150

for all five

Purity

Is the percentage of material acceptable?

Chromatographic separation quantifies the main peak against every related substance present, reported as a percentage of total peak area.

LC-MS/MS

Net Peptide Content

Does the vial contain the mass on the label?

Quantifies actual peptide mass per vial against a reference standard. Distinguishes true peptide content from counter-ions, residual solvent and water, which routinely account for a fifth of a lyophilized vial.

LC-MS/MS against a certified reference standard

Identity

Is it the peptide the label claims?

Molecular weight confirmation establishes that the material is the stated compound and not a cheaper analog with a similar retention time.

LC-MS molecular weight confirmation

pH

Is the reconstituted solution within range?

Measured on the reconstituted sample. A pH outside the expected range points to a formulation or stability problem well before it shows up as degradation.

Calibrated potentiometry

Fentanyl Presence Analysis

Is there any fentanyl in this material?

Targeted screen for fentanyl and its analogs. Contamination in a research peptide is a supply chain failure, and finding it is worth more than any other result on the certificate.

LC-MS/MS targeted screen

Conformity Across Samples

$50

Is every vial in the batch the same?

Additional vials from the same lot are tested independently and compared. This is what separates a controlled fill from a lucky one, and it is the test that catches inconsistent batches.

Replicate purity and content across 2 to 5 specimens

Sterility

$150

Is the product free of microbial contamination?

Detects bacterial and fungal contamination in the finished vial. Screening by PCR returns an answer in days rather than the fortnight a compendial culture takes.

PCR screen

Heavy Metals

$150

Did anything come through from synthesis?

Elemental analysis for lead, arsenic, cadmium and mercury, plus catalyst residues carried over from the synthesis route.

ICP-MS

Endotoxins

$150

Is the bacterial endotoxin load within limit?

Quantifies bacterial endotoxin in endotoxin units per milliliter. Endotoxins are fragments of the outer wall of certain bacteria, released when they die. They survive the sterilization that kills the bacteria themselves, and even trace amounts can cause fever and inflammation.

LAL, USP <85>

Monocyte Activation Test (MAT)

$800

Does it contain anything that would cause a fever?

An advanced, animal-free laboratory assay used to detect and quantify fever-causing substances (pyrogens) in medical and pharmaceutical products.

Human monocyte activation assay

Reconstitution Integrity Assessment (RIA)

$35

Does the powder actually go back into solution?

Checks that a dry peptide powder dissolves smoothly into a clear, particle-free solution. A vial that will not reconstitute cleanly is unusable whatever its purity says.

USP <790>

Redox (Oxidation-Reduction Potential)

$100

How prone is this material to oxidative degradation?

Measures how strongly a sample tends to promote or resist oxidation. Oxidation is a form of chemical degradation that can arise during manufacturing, in storage, or after reconstitution, through oxygen, moisture, light, temperature and impurities. The reading is an additional indicator of the chemical environment around the peptide, and of the conditions that shorten its life.

Oxidation-reduction potential, mV

Karl Fischer Titration

$300

How much water is in the vial, and does it stay that way?

Quantifies residual water content, and how it moves over time. Water is what most often drives a lyophilized peptide to degrade in storage, so the number is a stability measure as much as a composition one.

USP <921>

Full QC Panel

$600 per sample

Covers 10 of the tests above: Purity, Net Peptide Content, Identity, pH, Sterility, Heavy Metals, Endotoxins, Fentanyl Presence Analysis, Reconstitution Integrity Assessment (RIA) and Redox (Oxidation-Reduction Potential).

3 vials per sample.

Register free to order

Already registered? Sign in.

You can order Full QC panel or individual tests above

The panel is the whole characterization. Every test in it is also available on its own, at the price shown above, if you only need one answer.

Add to any sample

Conformity Testing

$50 each

Test additional vials from the same batch to verify sample-to-sample consistency.

Multi-Brand COA

$100 each

Additional COAs under different brand names — for white-label products.

Rush Processing (3 business days)

$150

Three business days guaranteed or the fee is credited back.

Next-day Processing

$300

Results the next business day.

Sample requirements

  • Full QC Panel: three vials, minimum 10 mg each.
  • Individual tests: one vial per test, minimum 10 mg each.
  • For quantities under 5 mg in total, contact the laboratory before shipping.

From vial to certificate.

  1. Place the order

    Tell us what is in the vial and choose the tests. Bulk orders can be uploaded as a spreadsheet.

  2. Ship the sample

    Print the confirmation, pack it with the vials, and send it by FedEx or UPS.

  3. We test it

    You can watch each test move from pending to complete as the work is done.

  4. Collect the certificate

    A branded PDF with a QR code your customers can scan to verify it themselves.

Before your first order.

Place the order in the portal first, print the confirmation, and include it in the box. Ship by FedEx or UPS to the address on your dashboard. Bubble wrap each vial individually. Shipments arriving without a packing slip take longer to process because they have to be matched by hand.

Yes. Enter each component and its amount when you place the order.

Yes. Your company name, logo and colors appear on it by default. If you sell the same product under other names, you can buy an additional certificate per brand for the same sample, up to five.

Every certificate carries a QR code. Scanning it opens the certificate on this site, served directly from the laboratory record. Nothing that arrives by email or sits on a seller's website can be checked that way, which is the point.

Yes. The certificate states what was measured. There is no arrangement under which an unfavourable result is withheld, and a laboratory that offered one would be worth nothing to your customers.

Yes. The LC-MS/MS method has been validated for the peptides we test.

It is actual peptide content in mg/vial.

Yes. Every certificate includes a representative LC-MS/MS chromatogram from the analysis behind the purity and identity results. Identity is confirmed by retention time and molecular mass, and the method notes on the certificate describe how each result was obtained.

Yes.

We cannot return any remaining material.

Yes. Every test we offer is listed with its price on this page. We need an additional vial for those tests.

Yes.